All Model and GPU Pairings

MiniMax M2.5/M2.7NVIDIA Blackwell

Running MiniMax M2.7 on B200

Quick answer

MiniMax M2.7 sustains 14,790 tokens/s per GPU on B200 at 50 tokens/s per user, which works out to $0.032 per million tokens at hyperscaler pricing, served by Dynamo vLLM. Fastest measured TTFT: 0.0 ms; fastest TPOT: 0.0 ms (each the best across all configs, not one run).

Benchmarked configs
142
Serving engines
Dynamo vLLM, TRTLLM, vLLM
Precisions
FP4, FP8
Run dates
2026-03-28 → 2026-06-13

Throughput at Every Interactivity Target

Serving is a trade-off: push more concurrent users through a GPU and each user's tokens arrive slower. The ladder below reads the measured frontier at each per-user speed target on a single-turn chat workload (8k input / 1k output), using the best engine and precision at that point.

Per-user targetTokens/s per GPU$ / 1M tokensEnginePrecision
30 tok/s16,448$0.029vLLMfp4
50 tok/s14,790$0.032Dynamo vLLMfp4
75 tok/s11,643$0.041Dynamo vLLMfp4
100 tok/s7,365$0.065Dynamo vLLMfp4
150 tok/s2,406$0.20vLLMfp4
200 tok/s--vLLMfp4

What Serving Actually Costs

Converting the 50 tokens/s per user operating point to $ per million total tokens across rental pricing tiers from the SemiAnalysis AI Cloud TCO model.

Pricing tier$ / GPU / hr$ / 1M tokens
Owning at Large Hyperscaler Volume$1.73$0.032
Retail$3.70$0.069

Frequently Asked Questions

How fast is MiniMax M2.7 on B200?
At an interactivity target of 50 tokens/s per user on a single-turn chat workload (8k input / 1k output), B200 sustains 14,790 tokens/s per GPU serving MiniMax M2.7 with Dynamo vLLM in FP4. Peak measured throughput across all configs is 20,733 tokens/s per GPU.
How much does it cost to serve MiniMax M2.7 on B200?
$0.032 per million total tokens at large-hyperscaler-volume ownership $/GPU/hr pricing, at 50 tokens/s per user. The retail rental tier is tabulated above; slower interactivity targets lower the cost further.
Which serving engines run MiniMax M2.7 on B200?
The runs behind this page used Dynamo vLLM, TRTLLM, vLLM in FP4, FP8, including disaggregated prefill and multi-node serving. Engines are rebuilt and re-benchmarked continuously, so the best config can change between visits.
How are these MiniMax M2.7 numbers measured?
Every number is measured on real B200 hardware by the InferenceX fleet, sweeping concurrency on a single-turn chat workload (8k input / 1k output) to trace the throughput-versus-interactivity frontier; the newest run landed on 2026-06-13. The same derivation powers the InferenceX overview leaderboard.

Explore the Data